6. PARAMETERS

6.1.7 Feeding function selection

No.
Symbol
PA05
*FTY
Feeding function selection
Select the feed length multiplication and the manual pulse generator input multiplication.
Parameter No.PA05
0 0
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting.
Feed length
Setting
multiplication
value
factor (STM)
[times]
0
1
1
10
2
100
3
1000
Manual pulse generator multiplication factor
0: 1 time
1: 10 times
2: 100 times
Feed unit
Absolute value
[ m]
command system
1
999.999 to
10
9999.99 to
100
99999.9 to
1000
999999 to
6 - 5
Initial
Unit
Setting range
value
0000h
Refer to the text.
Position data input range [mm]
Incremental value
command system
999.999
0 to
999.999
9999.99
0 to
9999.99
99999.9
0 to
99999.9
999999
0 to
999999