5. OPERATION
(2) Timing chart
Automatic/manual selection
(RYn6)
Selected point table No.
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Forward
rotation
Servo motor speed
Reverse
rotation
Proximity dog (DOG)
Rough match (RXn2)
Movement completion (RXnC)
Home position return
completion (RXn3/ZP)
Note. Configure a sequence that changes the point table selection earlier, considering the delay time of CC-Link communication.
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.
ON
OFF
4ms or more (Note)
ON
OFF
6ms or more
ON
OFF
Home position return speed
0r/min
3ms or less
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0
Moving distance after proximity dog
5 - 51
Home position shift distance
Proximity dog