14. OPTIONS AND AUXILIARY EQUIPMENT
14.10 No-fuse breakers, fuses, magnetic contactors
Always use one no-fuse breaker and one magnetic contactor with one servo amplifier. When using a fuse
instead of the no-fuse breaker, use the one having the specifications given in this section.
Servo amplifier
MR-J3-10T (1)
MR-J3-20T
MR-J3-20T1
MR-J3-40T
MR-J3-60T 70T 100T 40T1
MR-J3-200T
MR-J3-350T
MR-J3-500T
MR-J3-700T
MR-J3-11KT
MR-J3-15KT
MR-J3-22KT
MR-J3-60T4
MR-J3-100T4
MR-J3-200T4
MR-J3-350T4
MR-J3-500T4
MR-J3-700T4
MR-J3-11KT4
MR-J3-15KT4
MR-J3-22KT4
Note. When not using the servo amplifier as a UL/C-UL Standard compliant product, K5 class fuse can be used.
No-fuse breaker
Not using power
Using power factor
factor improving
improving reactor
reactor
30A frame 5A
30A frame 5A
30A frame 5A
30A frame 5A
30A frame 10A
30A frame 10A
30A frame 10A
30A frame 5A
30A frame 15A
30A frame 10A
30A frame 20A
30A frame 15A
30A frame 30A
30A frame 30A
50A frame 50A
50A frame 40A
100A frame 75A
50A frame 50A
100A frame 100A
100A frame 75A
225A frame 125A
100A frame 100A
225A frame 175A
225A frame 150A
30A frame 5A
30A frame 5A
30A frame 10A
30A frame 10A
30A frame 15A
30A frame 15A
30A frame 20A
30A frame 20A
30A frame 30A
30A frame 30A
50A frame 40A
50A frame 30A
60A frame 60A
50A frame 50A
100A frame 75A
60A frame 60A
225A frame 125A
100A frame 100A
14 - 68
Fuse
(Note) Class
Current [A]
10
10
15
15
20
40
70
125
150
200
T
250
350
10
15
25
35
50
65
100
150
175
Magnetic
Voltage
contactor
AC [V]
S-N10
S-N18
250
S-N20
S-N35
S-N50
S-N65
S-N95
S-N125
S-N10
600
S-N18
S-N20
S-N25
S-N35
S-N65

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents