Power Regeneration Common Converter - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

14. OPTIONS AND AUXILIARY EQUIPMENT
The following table lists the restrictions.
Item
Maximum number of connected servo amplifiers
Total of connectable servo amplifier capacities [kW]
Total of connectable servo motor rated currents [A]
Maximum servo amplifier capacity [kW]
Item
Maximum number of connected servo amplifiers
Total of connectable servo amplifier capacities [kW]
Total of connectable servo motor rated currents [A]
Maximum servo amplifier capacity [kW]
When using the FR-CV-(H), always install the dedicated stand-alone reactor (FR-CVL-(H)).

Power regeneration common converter

FR-CV-7.5K(-AT)
FR-CV-11 K(-AT)
FR-CV-15K(-AT)
FR-CV-22K(-AT)
FR-CV-30K(-AT)
FR-CV-37K
FR-CV-55K
FR-CV-H22K(-AT)
FR-CV-H30K(-AT)
FR-CV-H37K
FR-CV-H55K
7.5K
11K
3.75
5.5
33
46
3.5
5
FR-CV-H
22K
30K
11
15
90
115
11
15
Dedicated stand-alone reactor
FR-CVL-7.5K
FR-CVL-11K
FR-CVL-15K
FR-CVL-22K
FR-CVL-30K
FR-CVL-37K
FR-CVL-55K
FR-CVL-H22K
FR-CVL-H30K
FR-CVL-H37K
FR-CVL-H55K
14 - 47
FR-CV-
15K
22K
30K
6
7.5
11
15
61
90
115
7
11
15
37K
55K
6
18.5
27.5
145
215
15
22
37K
55K
18.5
27.5
145
215
15
22

Advertisement