Mitsubishi Electric MELSERVO-J3 Series Manual page 616

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

16. INDEXER POSITIONING OPERATION
No.
Symbol
PD17
For manufacturer setting
Do not change this value by any means.
PD18
PD19
*DIF
Response level setting
Used to select the input.
0 0 0
PD20 *DOP1 Function selection D-1
Select the stop processing at forward rotation stroke end (LSN)/reverse rotation
stroke end (LSN) OFF and the base circuit status at reset (RY(N 1)A or
RY(n 3)A) ON.
0
0
PD21
For manufacturer setting
Do not change this value by any means.
PD22
Not used in indexer positioning operation.
Do not change the parameter.
PD23
For manufacturer setting
Do not change this value by any means.
Name and function
Input filter
If external input signal causes chattering due
to noise, etc., input filter is used to suppress it.
0: None
1: 0.88[ms]
2: 1.77[ms]
3: 2.66[ms]
4: 3.55[ms]
5: 4.44[ms]
Stopping method used when forward rotation stroke end
(LSP), reverse rotation stroke end (LSN) device or software
limit is valid
0: Sudden stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (Setting contents is the same as for "1".)
3: Sudden stop (Setting contents is the same as for "0".)
Even in this case, when LSP or LSN is detected, home
position return is required again before executing automatic
operation. However, in the absolute position detection
system (parameter No.PA03:
return completion (ZP) can be turned on by turning on the
servo-on. In the case, executing another home position.
Selection of base circuit status at reset (RY(n 1)A or
RY(n 3)A)ON
0: Base circuit not switched off
1: Base circuit switched off
16 - 95
1), the home position
Initial
Unit
Setting range
value
0000h
0000h
0002h
Refer to
name and
function
column.
0010h
Refer to
name and
function
column.
0000h
0000h
0000h

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents