14. OPTIONS AND AUXILIARY EQUIPMENT
(2) Combination with MT-BR5-(H) resistor unit
Servo motor
thermal relay
(Note 4)
NFB
(Note 1)
Power
supply
Note 1. For power supply specifications, refer to section 1.2.
2. Always connect P
and P( ) terminals (Factory-wired). When using the power factor improving DC reactor, refer to section
1
14.11.
3. Connect the P/
and N/
brake unit malfunction.
4. For the servo amplifier of 400V class, a step-down transformer is required.
5. Contact rating: 1a contact, 110VAC_5A/220VAC_3A
Normal condition: TH1-TH2 is not conducting. Abnormal condition: TH1-TH2 is conducting.
6. Contact rating: 230VAC_0.3A/30VDC_0.3A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
7. Do not connect more than one cable to each P( ) and N( ) terminals of the servo amplifier.
8. Always connect BUE and SD terminals (Factory-wired).
9. The diagram is for when outputting the trouble (ALM) is enabled by changing the parameter. When disabling to output the
trouble (ALM), configure the power supply circuit to turn off the magnetic contactor after detecting an alarm occurrence on the
controller side.
10. For the servo amplifier of 22kW, do not connect a supplied regenerative resistor to the P and C terminals.
(Note 9)
ALM
EMG
RA2
RA1
Servo amplifier
MC
L
1
L
2
L
3
L
11
L
21
(Note 7)
terminals of the brake unit to a correct destination. Wrong connection results in servo amplifier and
ON
OFF
MC
MC
SK
CN6
1
EMG
17
DOCOM
24VDC
DICOM
5
ALM
RA1
(Note 9)
C
(Note 10)
P
(Note 2)
1
P(
)
N(
)
14 - 37
RA3
SK
MT-BR5-(H)
(Note 5)
TH1
P
RA3
TH2
PR
FR-BU2-(H)
PR
MSG
P/
SD
(Note 3)
A
N/
B
C
BUE
(Note 6)
(Note 8)
SD