Roll Feed Display Function In Roll Feed Mode - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

5. OPERATION

5.7 Roll feed display function in roll feed mode

With the roll feed display function, the servo amplifier can operate in the roll feed mode. The roll feed mode
uses the incremental system.
(1) Parameter settings
No.
Name
Absolute position
PA03
detection system
PC28
Function selection C-7
(2) Roll feed display function
At start up, the roll feed display function clears the status display of the current position and command
position to zero.
Forward
Servo motor speed
rotation
Display of current position
or command position
(3) Operation procedure
Changes are made only on the status display of the current position and commanded position. The same
operation procedure as that in each operation mode can be used.
Automatic operation
Manual operation
Home position return mode
Digit to
be set
Operation system
Selection between current
position display and command
position display
0r/min
0
Start
Operation procedure
Automatic operation according to the point table
JOG operation
Manual pulse generator operation
Setting
Setting item
value
(initial
value)
10.00
0
Start
5 - 56
Description
0
Make sure to set the incremental
system. The absolute position
detection system cannot be used.
1
Select roll feed display.
8.00
Details
Section 5.4.2
Section 5.5.1
Section 5.5.2
Section 5.6

Advertisement

Table of Contents

Troubleshooting

loading