Information for the Operator | Manual operation
1.2

Conducting the reference mark search

With the help of reference marks, the unit can assign axis positions of the encoder to
the machine.
If no reference marks for the encoder are provided by a defined coordinate system,
you need to perform a reference mark search before you start measuring.
If the reference mark search after unit start is active, then all of the unit's
functions will be disabled until the reference mark search has been
successfully completed.
Further information: "Reference marks (Encoder)", Page 96
For encoders with EnDat interface, the reference mark search is omitted
because the axes are referenced automatically.
If the reference mark search is active on the unit, then a wizard will ask you to
traverse the reference marks of the axes.
After logging in, follow the instructions of the wizard
The Reference symbol stops blinking upon successful completion of the
reference mark search.
Further information: "Operating elements of the position display", Page 39
Further information: "Activating the reference mark search", Page 129
Starting the reference mark search manually
If the reference mark search was not performed on startup, you can start it manually
later.
HEIDENHAIN | ND 7000 | Operating Instructions Drilling with radial drilling machines | 08/2023
Tap Manual operation in the main menu
The user interface for Manual operation appears.
Tap Auxiliary functions in the status bar
Tap Reference marks
Existing reference marks are cleared.
The Reference icon blinks.
Follow the instructions of the wizard
The Reference symbol stops blinking upon successful
completion of the reference mark search.
After a successful reference mark search, the product displays
the X, Y and Z axes.