M800VW/M80VW Series Connection and Setup Manual
23 Setting the Parameters and Date/Time

23.2 Setting the Parameters for the System Specifications

23.2 Setting the Parameters for the System Specifications
(1) On the Mainte screen, select [Mainte] and then [Psswd input]. Enter the machine parameter password in the setting area
and press the [INPUT] key.
(2) Go back to the Mainte screen. Then select [Param].
Set the parameters according to the system specifications.
"#1001 SYS_ON(System validation setup)"
"#1002 axisno(Number of axes)"
"#1003 iunit(Input setup unit)"
"#1004 ctrl_unit(Control unit)"
"#1005 plcunit(PLC unit)"
"#1006 mcmpunit(Machine error compensation unit)"
"#1037 cmdtyp(Command type)"
"#1039 spinno(Number of spindles)"
"#1155 DOOR_m"...Set to "100".
"#1156 DOOR_s"... Set to "100".
"#1511 DOORPm(Signal input device 1 for door interlock II: for each system)"
"#1512 DOORPs(Signal input device 2 for door interlock II: for each system)"
(3) After turning the power OFF and ON, select [Mainte] on the maintenance screen, switch the menu by the Menu change
button and then select [Format].
(4) When "Input the password" is displayed, enter the password for the machine parameter in the setting area and then press
[INPUT] key.
(5) When "Format NC memory? (Y/N)" is displayed, press "Y". "Format complete" will be displayed.
(6) Turn the power ON again and select [Mainte] --> [Psswd input] on the maintenance screen. Enter the machine parameter
password in the setting area and press the [INPUT] key.
Select [Param] again on the Mainte screen. Set the following parameters.
"#1010 srvunit" (Output unit(servo))
"#1013 axname" (Axis name)
 When the arbitrary axis exchange control is valid, set the axis names in "#12071 adr_abs[1]" to "#12078 adr_abs[8]".
"#1021 mcp_no" (Drive unit I/F channel No. (servo))
Set the following parameters as needed.
"#1014 incax" (Incremental command axis name)
 When the arbitrary axis exchange control is valid, set the incremental command axis name in "#12079 adr_inc[1]" to
"#12086 adr_inc[8]".
"#1015 cunit" (Command unit)
"#1017 rot" (Rotational axis)
"#1018 ccw" (Motor CCW)
"#1019 dia" (Diameter specification axis)
"#1020 sp_ax" (Spindle interpolation)
"#1022 axname2" (2nd axis name)
(7) Turn the power OFF and ON.