Cable Relating To Nc; Fcua-R050/R054 Cable - Mitsubishi Electric M800VW Series Connection And Set Up Manual

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
18 Cables

18.2 Cable Relating to NC

18.2 Cable Relating to NC

18.2.1 FCUA-R050/R054 Cable

Max. cable length: 30 m
Application: Synchronous encoder - control unit
ENC
ENC1
4
ENC1A (ENC2A)
14
ENC1A*(ENC2A*)
3
ENC1B (ENC2B)
13
ENC1B*(ENC2B*)
2
ENC1Z (ENC2Z)
12
ENC1Z*(ENC2Z*)
1
0V
11
0V
10
+5V
20
+5V
FG
[ENC1]
Plug: 10120-3000VL
Shell: 10320-52F0-008
Manufacturer: 3M
Note
(1) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
FCUA-R050
FCUA-R054
A
N
C
R
B
P
K
H
Wire material: UL1061-2464 AWG24 × 12P
Manufacturer: Oki Electric Cable
363
[FCUA-R050 cable]
Connector: MS3106B20-29S
Cable clamp: MS3057-12A
Manufacturer: ITT Cannon
[FCUA-R054 cable]
Connector: MS3108B20-29S
Cable clamp: MS3057-12A
Manufacturer: ITT Cannon
IB-1501612-C

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80vw seriesM850vwM830vwM80vwM800vs seriesM80v series

Table of Contents