Mitsubishi Electric M800VW Series Connection And Set Up Manual page 519

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
26 Setting the Position Detection System
26.1 Adjusting the Absolute Position Detection System
[When "#2059 zerbas" is set to "0"]
(6)
Set the "Zero-P". (*2)
Move the cursor to "Zero P" with the [ ↑ ] and [ ↓ ]
keys.
Input the distance from the basic machine coordinate
zero point to the machine end stopper in the input area
then press [INPUT].
Press the axis against the machine end stopper.
(7)
[When "#2059 zerbas" is set to "0"]
(8)
The axis pushes against the machine end stopper and
stops when the current reaches its limit.
[When "#2059 zerbas" is set to "1"]
The axis pushes against the machine end stopper, and
the current reaches its limit, the axis reverses and
moves at the pushing speed (set by "#2055 pushf").
Then the axis stops at the first grid point.
Move the cursor to "Zero-P" with the [ ↑ ] and [ ↓ ]
keys.
Input the distance from basic machine coordinate sys-
tem zero point to the grid point immediately preceding
the machine end stopper then press [INPUT].
The zero point initial setting is now complete. After initializing all axes, turn the power OFF and ON.
IB-1501612-C
The input value will be registered in the "Zero-P" area.
State: [Stopper]
Machine end: Distance between the machine end stopper
and the grid point immediately before the stopper
State: [Complete]
Machine end: 0.000
Machine position: Current machine position
State: [Complete]
Machine end: Distance between the machine end stopper
and the grid point immediately before the stopper
Machine position: Current machine position
486

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80vw seriesM850vwM830vwM80vwM800vs seriesM80v series

Table of Contents