4 General Specifications
4.3 Control Unit [M800VW]
[Outline of analog signal input circuit]
<Input circuit>
AIO
AI
0V
<Input conditions>
Analog input voltage
Max. input rating (*1)
Resolution
Repeatability
Tolerance
(*1) This indicates the input voltage which must not be exceeded even in an instant.
(*2) Except when the accuracy is affected by the noise.
[Outline of analog signal output circuit]
<Output circuit>
AIO
Load
500Ω
AO
0V
<Output conditions>
Analog output voltage
-10 to 10 V (±5%)
Resolution
10 V/4095 = 2.44 mV
Load conditions
10 kΩ load resistance
Output resistance value
500 Ω
ADC
-10 to 10 V
±15 V
|-10 to +10 V|/4095 = 4.88 mV
Within ±25 mV (*2)
±0.35 V
DAC