M800VW/M80VW Series Connection and Setup Manual
18 Cables
18.2 Cable Relating to NC

18.2.8 J023/J024/J025 Cable

Max. cable length: 20 m
Application: Manual pulse generator cable (5V)
MPG
MPG
4
HA1A
14
HA1B
10
+5V
1
0V
3
HA2A
13
HA2B
20
+5V
11
0V
2
HA3A
12
HA3B
19
+5V
15
0V
FG
[MPG]
Connector: 10120-3000PE
Case: 10320-52F0-008
Manufacturer: 3M
Cable name
1ch
J023 cable
J024 cable
J025 cable
○ : Usable channel
Unconnectable to control unit side
Note
(1) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
(2) The cables for 1ch and 2ch are compatible with F023 or F024 cable of the conventional model.
(3) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly otherwise the
connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20 ±0.05 Nꞏm)
HA1
HB1
5V1
0V1
HA2
HB2
5V2
0V2
HA3
HB3
5V3
0V3
Wire material: UL2464 U-TKVVBS AWG22 × 6P
Manufacturer: Tachii Electric Wire
2ch
3ch
1ch
2ch
3ch
369
[1ch][2ch][3ch]
Crimp terminal: R1.25-3 × 12
Manufacturer: JST
IB-1501612-C