M800VW/M80VW Series Connection and Setup Manual
20 Setting the Hardware
20.6 Connecting and Setting the Remote I/O Unit

20.6.6 Thermistor Input Interface

 By connecting the remote I/O unit with thermistor, up to 12 points of thermistor input are available.
For details on units with the thermistor input function, refer to "4.10 Remote I/O Unit".
 Up to 12 points of the thermistor are detected in the ascending order of the channel No. and station No. of the remote I/O
unit. The file registers outputting temperature information are assigned inputs (thermistor input n (TIn)) but are not assigned
to the 13th or later thermistor input. The relationship between thermistor inputs and file registers is as follows:
[PLC input signals]
Through the interface you can read the temperature sensed by a thermistor connected to the designated connector of
thermistor input-equipped remote I/O unit.
Channel
TI0
ZR13028
TI1
ZR13029
TI2
ZR13030
TI3
ZR13031
TI4
ZR13032
TI5
ZR13033
TI6
ZR13034
TI7
ZR13035
TI8
ZR13036
TI9
ZR13037
TI10
ZR13038
TI11
ZR13039
IB-1501612-C
File register
The thermistor voltage acquired with the thermistor input-equipped re-
mote I/O unit is input after converted to a temperature value per PLC me-
dium-speed cycle.
One station of remote I/O has 4 thermistor inputs, thus 4 PLC medium-
speed cycles are required for the inputs of one station.
Data update cycle