The method for connecting to each unit and device from the control unit is explained in this chapter.
7.1 Control Unit Connection System Drawing

7.1.1 M800VW

Control unit
J070/J071
cable (*)
G123
terminal
EMG
Emergency stop (*1)
J303
cable (*)
GDI
J210
cable (*)
RIO3
J210
cable (*)
RIO1/RIO2
J395/J396/G380
OPTH1/OPTH2
J030/J031
cable (*)
SIO
J100
cable (*)
SKIP
J220
cable (*)
AIO
J026/J027
cable (*)
Function
EXT1/EXT2
expansion unit
Function
EXT3/EXT4
expansion unit
J303
cable (*)
LAN1
J303
cable (*)
LAN3
SD memory card
SD
RIO8
(*1) Use when installing an emergency stop switch in the electric cabinet. (Connection cable: J120 cable) When this connec-
tor is not used, connect a terminator connector (G123 cable). G123 terminal cable comes with the control unit.
Note
(1) For connection to the machine operation panel, refer to the chapter "16 Connection of Machine Operation Panel".
(2) The section indicated with asterisk (*) indicates cable to be wired outside the electric cabinet.
Since the cable could be affected by the exogenous noise depending on the environment, the following noise counter-
measure is recommended.
Expose the cable by removing a part of the cable sheath and use the shield clamp for the exogenous noise countermeasure.
Shield
When you cannot use the shield clamp, install a ferrite core as a substitute.
<Related item>
Shield clamp fitting: "44.6.1 Shield Clamp Fitting"
Ferrite core: "44.6.2 Ferrite Core"
IB-1501612-C
24VDC Stabilized
power supply
Personal computer unit
GDI
Operation panel I/O unit
RIO3
Remote I/O unit or laser I/F unit
cable
Servo/Spindle drive unit
RS-232C device
Skip input (Sensor input)
Analog IO, or
5V manual pulse generator
(*)
Synchronous feed encoder, or
5V manual pulse generator
Network, or
Vibration cutting expansion unit
Network
Network
(*)
Energy
measuring units
Cable
Display unit
236