M800VW/M80VW Series Connection and Setup Manual
4 General Specifications
4.10 Remote I/O Unit
[Outline of digital signal output circuit]
Use within the specification ranges shown below.
<Output circuit>
SDO1
SYR00A
Load
|
SYR03A
SYR00A
|
SYR03A
SDO2
SYR00B
Load
|
SYR03B
SYR00B
|
SYR03B
<Output conditions>
Insulation method
Output method
Contact structure
Rated voltage
Rated current
Minimum applicable load
Operation time
Response time
Return time
Life
Max. operation frequency
IB-1501612-C
24VDC
Relay feedback
Welding check LED
Insulated by relay
Non-voltage A contact
Forced guide style relay
250 VAC, 125 VDC
6 A
1 mA, 5 VDC
20 ms or less (contact bounce not included)
8 ms or less (contact bounce not included)
20 ms or less (contact bounce not included)
100,000 times or more with 250 VAC, 6 A resistant load (opening/closing frequency: 20 times/min)
100,000 times or more with 30 VDC, 6 A resistant load (opening/closing frequency: 20 times/min)
500,000 times or more with 250 VAC, 1 A resistant load (opening/closing frequency: 30 times/min)
500,000 times or more with 30 VDC, 1 A resistant load (opening/closing frequency: 30 times/min)
100,000 times or more with 15 AC: 240 VAC, 2 A induction load (opening/closing frequency: 20 times/min,
cosφ = 0.3)
100,000 times or more with 13 DC: 24 VDC, 1 A induction load (opening/closing frequency: 20 times/min,
L/R = 48 ms)
20 times/min
Control
circuit
Control
circuit
124