M800VW/M80VW Series Connection and Setup Manual
37 Adjust S-analog Screen

37.1 Adjustment Preparations

37.1 Adjustment Preparations
The PLC must be stopped when performing spindle analog output adjustments by one of the following methods below:
Operation methods (when stopping the PLC with the rotary switch)
Set the rotary switch CS2 in the upper part of the unit
(1)
to "1".
Operation methods (when stopping the PLC on the maintenance screen)
Press the function key [MAINTE] and then press the
(1)
menu [MAINTE].
Press [Psswd input].
(2)
Enter the machine tool builder password.
(3)
Press the menu [PLC STOP] and then press [Y] key.
(4)

37.2 Performing Automatic Adjustments

Automatic adjustment will execute "0 V offset adjustment" and "+ gain adjustment" for the remote I/O analog outputs (max.
4ch) connected to the main unit. Negative (-) gain will be treated as the equal to positive (+) gain.
Operation methods
Press the menu [Auto adjust].
(1)
Press the[Y] or [ INPUT] key.
(2)
The manual adjustment related menu is displayed in gray during the automatic adjustment, and manual adjustments will be
disabled. Switching to other screens is also disabled at this time.
When automatic adjustment is complete, an operation message "Auto adjust complete" will display.
The highlighting of the menu [Auto adjust] is cleared and the cursor is returned to where it was before the auto adjustment.
The menu [Manual adjust] returns to the normal display and manual adjustment can be performed.
The PLC is stopped.
The PLC is stopped.
An operation message "Execute? (Y/N)" will display.
Automatic adjustment begins.
The operation message "Auto adjusting" appears.