Connecting I/O Device Via Fl-Net - Mitsubishi Electric M800VW Series Connection And Set Up Manual

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
7 Connection of Control Unit
7.11 Connecting Device via Function Expansion Unit

7.11.2.5 Connecting I/O Device via FL-net

The expansion unit FCU8-EX568 functions as a node of FL-net. Connect the FL-net-compatible equipment with an ethernet
cable (category 5e or above and twisted pair shield cable).
For details, refer to the "M800/M80 Series FL-net Specifications Manual".
FL-net expansion unit
(FCU8-EX568)
FL-net
network connector
(Only LAN1)
Note
(1) FL-net expansion unit is equipped with two RJ-45 connectors (LAN1 and LAN2); however, the function of FL-net is avail-
able only on LAN1. Do not connect any cable to LAN2 port.
Countermeasures for Ethernet cable noise
When the FL-net expansion unit is being used, expose the cable by removing a part of the cable sheath and use the shield
clamp for the exogenous noise countermeasure.
When you cannot use the shield clamp, install a ferrite core as a substitute to ethernet cable (near the expansion unit).
(Recommended model name: ZCAT2032-0930(-BK))
[Related items]
Shield Clamp Fittings: "44.6.1 Shield Clamp Fitting"
Ferrite Core: "44.6.2 Ferrite Core"
FL-net-compatible equipment
Industrial switching hub
Ethernet cable
(category 5e or above and
twisted pair cable with shield)
Ethernet cable
Shield
Industrial switching hub
FL-net-compatible
equipment
267
FL-net-compatible
equipment
FL-net-compatible
equipment
(* Prepared by MTB)