Mitsubishi Electric M800VW Series Connection And Set Up Manual page 513

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
26 Setting the Position Detection System
26.1 Adjusting the Absolute Position Detection System
(6)
Move the cursor to "Zero P" with the [ ↑ ] and [ ↓ ]
keys.
Enter the value for "Zero-P" in the input area and press
the [INPUT] key.
Move the axis to the mechanical basic position.
(7)
(8)
Move the cursor to "Origin-P" with the [ ↑ ] and [ ↓ ]
keys.
Input "1" in the input area and press the [INPUT] key.
The zero point initial setting is now complete. After initializing all axes, turn the power OFF and ON.
Start point
Basic machine coordinate
system zero point
Zero return parameter
"#2037 G53ofs"
"#2 Zero-P"
Note
 To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P", and then turn the
power OFF and ON.
IB-1501612-C
(7)
Reference
position
480
The input value will be registered in the "Zero-P" area.
The input value will be registered in the "Origin-P" area.
State: [Complete]
Machine end: 0.000
Machine position: Value set for "Zero-P"
Mechanical basic
position

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80vw seriesM850vwM830vwM80vwM800vs seriesM80v series

Table of Contents