MDS-EX-CV/CVH Series Specifications and Instruction Manual
7 Setup

7.1 Setting the Initial Parameters for the Drive Unit

7.1 Setting the Initial Parameters for the Drive Unit
The servo and spindle related parameters must be set before the servo and spindle system can be started up. The servo and
spindle related parameters are input from the NC. As the input method differs according to the NC being used, refer to each
NC Instruction Manual.

7.1.1 Servo Parameter

(PR)
#2236
MDS-E/EH Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used
Deceleration and stop function at
power failure
Retraction function at power failure
bit B-8 : rtyp
Not used. Set to "0".
bit 7-0 : ptyp External emergency stop setting
When the emergency stop input signal of the power supply unit is "disabled"
Power supply unit is not connected
MDS-E-CV-37/ MDS-EH-CV-37
MDS-E-CV-75/ MDS-EH-CV-75
When the emergency stop input signal of the power supply unit is "enabled"
(*) Set the power supply rotary switch to "4".
Power supply unit is not connected
MDS-E-CV-37/ MDS-EH-CV-37
MDS-E-CV-75/ MDS-EH-CV-75
IB-1501700-A
SV036
PTYP
: 0
: 8
: C
: 00
: 04
: 08
: 00
: 44
: 48
Power supply type/ Regenerative resistor type
32
ptyp
rtyp
amp