4 General Specifications
4.11 Laser I/F Unit
[Outline of analog signal input circuit]
<Input circuit>
Laser oscillator
CONC
AI0
0V
<Input conditions>
Analog input voltage
Max. input rating (*1)
Resolution
Repeatability
Tolerance
(*1) This indicates the input voltage which must not be exceeded even in an instant.
(*2) Except when the accuracy is affected by the noise.
[Outline of analog signal output circuit]
<Output circuit>
Laser oscillator
AO0
0V
<Output conditions>
Analog output voltage
Resolution
Load conditions
Output resistance value
Maximum frequency (*1)
Duty ratio (*1)
Minimum pulse width (*1)
(*1) This indicates the conditions when PWM signal is output from analog signal output.
When the PWM signal is output from DO16, the PWM signal cannot be output from the analog signal output.
IB-1501612-C
R
ADC
R
0 V to 10 V
12.5 V
+10 V/16383 = 0.6104 mV
±25 mV (*2)
±0.35 V
CONC
DAC
30Ω
0 V to 10 V (±5%)
+10 V/16383 = 0.6104 mV
External load resistance value 2.2
kΩ or more
30 Ω
1 Hz to 4000 Hz (Setting unit: 1 Hz)
0.0% to 100.0% (Setting unit: 0.1%)
50 μs