38 Device Open Parameter Screen
Display items
Display item
(1) Parameter No.
(2) Device allocation
(3) Data type
(4) Number of data
Displays the parameter Nos.(maximum of 100).
Set the head device which designates the divided area.
It is possible to designate the device allocation which overlaps with other
groups.
When "0" is set to the device allocation, it clears the settings (data type, dis-
play format etc.) of the target group.
When an odd number address is set for the device allocation, DWORD
cannot be designated for the data type.
Sets the data type (BYTE, WORD, DWORD, WORD(BIT)) for the allocated
space.
BYTE: Allocates space in 1-byte increments.
WORD: Allocates space in 2-byte increments.
DWORD: Allocates space in 4-byte increments.
WORD(BIT): Allocates space in 2-byte increments.
DWORD cannot be designated when the device allocation is an odd num-
ber address.
BIT format is valid for the display format when WORD(BIT) is designated.
The data type can also be designated by pressing the menu [BYTE],
[WORD], [DWORD], or [WORD(BIT)].
Set the number of data in the allocation area.
Number of data available to designate varies depending on the designated
data type.
When the number of data is "0", the target group will be invalid.
(Example)
Device allocation: R8400
Data type: DWORD
Number of data: 100
R8400
DWORD
R8402
DWORD
R8598
DWORD
Details
400byte
605
Setting range
-
R8300 to R9799
R18300 to R19799
R28300 to R29799
0
0: WORD
1: DWORD
2: BYTE
3: WORD(BIT)
0 to 3000
Depends on the device al-
location and data type.