R2-Tm Terminator Connector - Mitsubishi Electric M800VW Series Connection And Set Up Manual

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
18 Cables
18.2 Cable Relating to NC

18.2.24 R2-TM Terminator Connector

Application: Terminator for remote I/O interface
B
A
R2-TM
TXRX
1A
TXRX*
1B
2A
0V
2B
3A
FG
3B
[R2-TM]
Connector: 1-1318119-3
Contact: 1318108-1
Manufacturer: TE Connectivity
Resistor: 110 Ω 1/4 W
Note
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing they are compatible with
the specifications.
(2) Cover the 110 Ω terminator with a black insulation tube.
(3) Stamp the connector name "R2-TM" in white on the rear of the connector.
IB-1501612-C
1
2
3
R2-TM