4 General Specifications

4.10 Remote I/O Unit

4.10 Remote I/O Unit
Types of signals described on the list of units can be input/output from the remote I/O unit (FCU8-DXxxx) according to the
type and No. of contacts. Remote I/O units are used by being connected to the control unit or the operation panel I/O unit.
Multiple remote I/O units can be used as long as the total number of occupied stations is 64 or less.
Note
(1) The maximum connectable number of remote I/O units is 32.

4.10.1 List of Units

Classification
DI 24 V/0 V common input [32 points]
DO Source output [32 points]
DI 24 V/0 V common input [64 points]
DO Source output [48 points]
DI 24 V/0 V common input [64 points]
DO Source output [48 points]
AO analog output [1 point]
AI analog input [4 points]
AO analog output [1 point]
DI 0 V common input [16 points]
DO Source output (large capacity) [8 points]
DI 0 V common input [16 points]
DO Source output (large capacity) [8 points]
Safety DI 0 V common input [8 points]
Safety DO Source output (large capacity) [4
points]
Safety DI 0 V common input [8 points]
Safety DO Source output (large capacity) [4
points]
DI 24 V/0 V common input [32 points]
DO Source output [32 points]
Safety DI 0V common input [8 points] (*1)
Safety relay output [4 points] (*2)
Thermistor input (12 points)
Multi-analog input [4 points] (*3)
(*1) Safety DI uses 16 points of terminal because of the duplication wiring.
(*2) Safety relay output uses 8 points of terminal because of the duplication wiring.
(*3) Voltage input, current input, thermocouple input and resistance temperature detector input are selected for each CH.
IB-1501612-C
Type
Components
Base card
FCU8-DX220
RIO 2.0 connector set
Base card
FCU8-DX230
RIO 2.0 connector set
Base card
FCU8-DX231
RIO 2.0 connector set
Base card
FCU8-DX202
RIO 2.0 connector set
Base card
FCU8-DX213
RIO 2.0 connector set
Base card
FCU8-DX213-1
RIO 2.0 connector set
Base card
FCU8-DX654
RIO 2.0 connector set
Base card
FCU8-DX654-1
RIO 2.0 connector set
Base card
FCU8-DX651
Add-on card
RIO 2.0 connector set
Base card
FCU8-DX408
RIO 2.0 connector set
Base card
FCU8-DX409
RIO 2.0 connector set
96
Remarks
DI: 32-point 24 V/0 V common type
DO: 32-point source type (200 mA/point)
Number of occupied stations: 1
DI: 64-point 24 V/0 V common type
DO: 48-point source type (200 mA/point)
Number of occupied stations: 2
DI: 64-point 24 V/0 V common type
DO Source type [48 points] (200 mA/point)
AO: 1 point
Number of occupied stations: 2
AI: 4 points
AO: 1 point
Number of occupied stations: 1
DI: 16-point 0 V common type (3 mA/point)
DO: 8-point source type (2 A/point)
Number of occupied stations: 1
DI: 16-point 0 V common type (9 mA/point)
DO: 8-point source type (2 A/point)
Number of occupied stations: 1
Safety DI: 8-point 0 V common type (3 mA/point)
Safety DO: 4-point source type (2 A/point)
Number of occupied stations: 2
Safety DI: 8-point 0 V common type (9 mA/point)
Safety DO: 4-point source type (2 A/point)
Number of occupied stations: 2
DI: 24 V/0 V common type [32 points]
DO: 32-point source type (200 mA/point)
Safety DI: 8-point 0 V common type
Safety relay: 4 points (non-voltage contact)
Relay contact welding detection
Number of occupied stations: 3
Thermistor input: 12 points
Number of occupied stations: 3
Multi-analog input: 4 points
Number of occupied stations: 4