M800VW/M80VW Series Connection and Setup Manual
11 Connection of Remote I/O Unit
11.11 Connecting with Multi-analog Input Signal (FCU8-DX409)
AI: DFMC1, 5/12-ST-3, 5-LR (Phoenix Contact)
<Applicable cable>
Solid wire
Twisted wire
Bar terminal with insulation collar
Bar terminal without insulation collar
Stripping line length
<Wire mounting tool (driver) type>
Type
: SZS 0, 4X2, 5 VDE
Manufacturer
: Phoenix Contact
<Bar terminal type>
Type
: AI series
Manufacturer
: Phoenix Contact
<Crimp tool type>
Type
: CRIMPFOX 6
Manufacturer
: Phoenix Contact
<Recommended cable with shield material>
Type
: HK-SB/20276XL LF
Manufacturer
: Taiyo Cabletec
(Select the wire diameter from AI connector specification.)
Maximum cable length is 50 m. Line resistance is 10 Ω or less, and line resistance difference is 0.1 Ω or less (see below).
Machine
side
- Line resistance of conducting wire A and B is 10Ω or less.
- Line resistance difference between conducting wire A and B is 0.1Ω or less
Resistance
temperature
detector
- Line resistance of conducting wire A, B C and D is 10Ω or less.
- Each line resistance difference between conducting wire A, B C and D is 0.1Ω or less
2
: 0.2-1.5 mm
2
: 0.2-1.5 mm
2
: 0.25-0.75mm
2
: 0.25-1.5mm
: 10 mm
Conducting wire A
Conducting wire B
Conducting wire A
Conducting wire B
Conducting wire C
Conducting wire D
323
FCU8-DX409 : AI
Connector for analog input
IB-1501612-C