J100 Cable - Mitsubishi Electric M800VW Series Connection And Set Up Manual

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
18 Cables
18.2 Cable Relating to NC

18.2.12 J100 Cable

Max. cable length: 20 m
Application: Skip
SKIP
SKIP
1
COM
11
COM
2
SKIP0
12
SKIP1
3
SKIP2
13
SKIP3
5
COM
COM
15
SKIP4
7
17
SKIP5
8
SKIP6
SKIP7
18
FG
[SKIP]
Connector: 10120-3000PE
Case: 10320-52F0-008
Manufacturer: 3M
Note
(1) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
(2) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly otherwise the
connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20 ±0.05 Nꞏm)
COM
COM
SK0
SK1
SK2
SK3
COM
COM
SK4
SK5
SK6
SK7
Wire material: UL2464 U-TKVVBS AWG24 × 6P
Manufacturer: Tachii Electric Wire
373
Crimp terminal: R1.25-3.5 × 12
Manufacturer: JST
IB-1501612-C