Shield Clamping Of Cables - Mitsubishi Electric M800VW Series Connection And Set Up Manual

Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800VW/M80VW Series Connection and Setup Manual
5 Installation
5.2 Noise Countermeasures

5.2.2 Shield Clamping of Cables

The shield of the shield cable connected to the control unit and drive unit must be connected to the grounding plate to stabilize
operation while preventing malfunctioning due to noise.
The shield can be connected to the grounding plate with lead wires or clamp fittings. Refer to the following drawings to treat
the shield cable.
 Example of connection with lead wire
Soldering
Shield
Example of lead wire treatment
 Example of connection with clamp fitting
Shield
Clamp fitting
 Peel part of the cable sheath and expose the shield as shown in the drawing. Press the exposed part against the grounding
plate with the cable clamp fittings.
 If the cables are thin, several can be bundled and clamped together.
 Use adequate force when tightening the cable so that the wire material is not damaged.
 Connect each grounding plate together and ground them at one point.
IB-1501612-C
Cable
Cable
Cable
Grounding plate
Less than
0.8m
208
Unit
Lead wire
Unit
Cable
Shield
Clamp fitting
Grounding plate

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80vw seriesM850vwM830vwM80vwM800vs seriesM80v series