3.3.31 Vibration Suppression Function(Fn205 - YASKAWA Sigma-V Series User Manual

Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

3.3.31 Vibration Suppression Function(Fn205)
This function suppresses low and transient vibration (trembling) of
approximately 1 Hz to 100 Hz, primarily resulting from the base vibrating or
shaking during positioning.
(1)
Conditions that Disable This Function
This function is disabled in the following settings.
• When the Write Prohibited Setting (Fn010 = 0001) is set.
• When the control method is selected other than position control.
• When the automatic gain switching is disabled.
• When the tuning less function is enabled (Pn140 = n.
(2)
Display Example
R U N
F n 2 0 4 : A − V i b S u p
F n 2 0 5 : V i b S u p
F n 2 0 6 : E a s y F F T
F n 2 0 7 : V - M o n i t o r
(3)
Operation Keys
Functions (The disabled keys are not included.)
− F U N C T I O N −
Used to reflect "Measure f" indications on "Setting f."
Used to move the next digit.
Used for fine adjustment of frequency.
Returns to the main menu of Utility Function Mode.
3.3 Operation Method for Each Utility Function
− V i b S u p −
R U N
M e a s u r e f = − − − − − H z
S e t t i n g f = 0 5 0 . 0 H z
0).
3-97
9 3

Advertisement

Table of Contents
loading