(4)
Operation Example
Step
Display Example
B B
F n 0 2 0 : S − O r i g S e t
1
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
B B
2
S o f t w a r e R e s e t
R E S E T 1
B B
3
S o f t w a r e R e s e t
R E S E T 5
B B
4
S o f t w a r e R e s e t
F i l e F i r s t L o a d i n g
5
P l e a s e W a i t . . .
B B
F n 0 2 0 : S − O r i g S e t
6
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
3.3 Operation Method for Each Utility Function
− F U N C T I O N −
− F U N C T I O N −
Description
Press the
Key to open the Utility Func-
tion Mode main menu, and select Fn030 using
the
or
Key.
Press the
Key to change to the Fn030
main window.
Press either the
or
"RESET5" will be displayed.
While "RESET5" is displayed, press
the
Key to reset the SERVOPACK
using a software program.
After the SERVOPACK has been successfully
reset, you will be returned to the window seen
at power ON. The window then changes to
the Parameter/Monitor display mode.
Press the
Key.
The display returns to the Utility Function
Mode main menu.
Key, and
9 3