(4)
Operation Example
Step
B B
F n 0 0 4 : P r o g r a m J O G
1
F n 0 0 5 : P r m I n i t
F n 0 0 6 : A l m H i s t C l r
F n 0 0 8 : M t u r n C l r
B B
P a r a m e t e r l n i t
2
S t a r t
R e t u r n : [ S E T ]
B B
P a r a m e t e r l n i t
3
S t a r t
R e t u r n : [ S E T ]
Note: 1. The Initialize Parameter Settings (Fn005) initializes the parameter settings. However,
some parameters require turning the power OFF then ON to validate the changes. Be
sure to turn the power OFF then ON again.
2. "A.941" means that the setting validation is required to validate the new settings.
After having changed the parameter setting, be sure to execute the setting validation.
3.3 Operation Method for Each Utility Function
Display Example
− F U N C T I O N −
: [ D A T A ]
: [ D A T A ]
Description
Press the
Key to open the Utility
Function Mode main menu, and select
Fn005 using the
or
Press the
Key.
The display is switched to the execution
display of Fn005 (Initialize parameter
setting).
Note: If the display is not switched and
"NO-OP" is displayed in the sta-
tus display, the Write Prohibited
Setting (Fn010 = 0001) is set.
Check the setting and reset.
Press the
Key to initialize parame-
ters.
During initialization, "Parameter Init" is
blinking in the display. After the initial-
ization is completed, "Parameter Init"
stops blinking and the status display
changes as follows: "BB" to "Done" to
"A.941"
Note: Press the
Key not to initial-
ize parameters. The display
returns to the Utility Function
Mode main menu.
Key.
9 3
3-21