Polaris RZR XP 1000 2014 Service Manual page 48

Table of Contents

Advertisement

MAINTENANCE
6. Remove the four T40 bolts retaining the valve cover.
7. The engine will need to be rotated four times to
inspect all eight valve clearances
be measured at each camshaft lobe position.
Remove spark plugs to aid engine rotation.
8. Rotate the drive clutch counter-clockwise until the
g
cam lobes
above the valves you are inspecting
are facing up.
2.14
f
. Two valves can
NOTE
9. Measure the valve clearance using a feeler gauge.
10. If the valve clearance is out of specification, see
Chapter 3 – Valve Clearance Adjustment, page 3.85.
MEASUREMENT
Intake Valve Clearance (cold):
.006 ± .002" (0.15 ± 0.05 mm)
Exhaust Valve Clearance (cold):
.008 ± .002" (0.20 ± 0.05 mm)
11. Repeat steps 18-20 until all eight valves have been
inspected.
12. If previously removed, apply anti-seize compound to
the spark plug threads and reinstall the spark plugs.
Torque spark plugs to specification.
TORQUE
Spark Plug Torque:
7 ft-lbs (10 Nm)
13. Inspect the valve cover seal and replace if
necessary.
14. Install NEW isolators on the valve cover bolts. Install
the valve cover and the four T40 bolts. Torque bolts
to specification.
TORQUE
Valve Cover Bolts:
7 ft-lbs (10 Nm)
15. Install the spark plug wires back into their correct
location.
16. Install the push rivet that retains the heat shield to
the frame cross member.
9926816 R07 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.

Advertisement

Table of Contents
loading

Table of Contents