Command 0X0E - Get Information - Magtek DynaPro Go Programmer's Manual

Handheld pin pad device with msr/contact/contactless
Table of Contents

Advertisement

4 - Command Set

4.3.13 Command 0x0E - Get Information

The host uses this command to retrieve various types of information from the device.
Table 4-15 - Usage Table for Command 0x0E
Bit
7
Byte 0
0x0E
Byte 1
Info ID (see Table 4-17)
If the host is retrieving Info ID 0x80, the host should call this command in Get mode, and if the device
has keys injected, the command returns the requested KCV/Hash.
If the host is using any Info ID other than 0x80, it should follow these steps:
1) Call this command in Set mode, specifying the Info ID from Table 4-17. If an error occurs, the
device terminates the command and reports the error in ACKSTS of Command 0x01 - Response
ACK. For a full list of error codes, see Command 0x01 - Response ACK.
2) Call this command in Get mode.
3) The device responds with the requested data.
Table 4-16 - Usage Table for Command 0x0E
Bit
7
Byte 0
0x0E
Byte 1
Info ID (see Table 4-17)
Key Status, if Info ID < 0x80:
0x00 = Empty (default)
0x01 = OK
Byte 2
0x02 = Exhausted
Key Status, if Info ID = 0x80:
0x00..0x05 = KCV type (see Table 4-17)
Byte 3
Data length (see Table 4-17); default value is 0
Byte 4..63
Block data
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer's Manual (COMMANDS)
6
5
4
6
5
4
Page 60 of 247 (D998200136-31)
3
2
1
3
2
1
0
0