Configuring Circuit Properties - Cabletron Systems CyberSWITCH CSX150 User Manual

Enterasys cyberswitch csx150: user guide
Hide thumbs Also See for CyberSWITCH CSX150:
Table of Contents

Advertisement

USER'S GUIDE
C
C
ONFIGURING
IRCUIT
The example screen below shows basic property information for a PRI 5ESS circuit. All of the
shown configured values were automatically incorporated from the site template associated with
the system.
If the circuit's configuration varies from the values taken from the site template, you can edit these
values.
Notice that there are also blank fields: Hunt Group Number and Directory Number. Depending on the
configuration needed for the system, you may want to enter information in these fields. These fields
are defined as follows:
Hunt Group Number
Only available for BRI or PRI circuits. A hunt group is a series of telephone lines organized in
such a way that if the first line is busy the next line is hunted and so on until a free line is found.
The hunt group number is the telephone number used for this circuit's hunt group.
Directory Number
Only available for PRI circuits. (A BRI circuit's directory number is configured under the Data
Links tab.) This is the telephone number used for this circuit. When connection groups are
formed, this number is used for initial population of the phone list. For example, if you
configure a directory number for Site1, then create a connection group containing Site1 and a
second site, Site2, Site2 would add Site1's directory number to its list of numbers to use to
connect to Site1.