Calibrating The Load Cells - Stratasys J4100 User Manual

3d printing system
Table of Contents

Advertisement

Stratasys J4100 User Guide

Calibrating the Load Cells

Load cells are sensors that measure the weight of the material containers and
the waste container in the printer. It is important that you periodically check that
the weight measurements are accurate to prevent unnecessary waste of printing
materials or printer malfunctions.
To calibrate load cells:
1. Start the Load Cell Calibration wizard from the Options menu.
2. In the following screen, select one or more load cells that you want to
3. Make sure that there are no containers on the load cells that you want to
4. In the next wizard screen, observe the numbers and wait until the weight level
5. Select the check box, and click Next.
DOC-26000 Rev. C
calibrate.
Figure 4-123 Load cell selection
calibrate, and click Next.
is relatively stable—two units above or below the average level shown.
Figure 4-124 Weight stabilization
4 Operating and Maintaining the Printer
4-87