Operating & Maintaining the Objet30 3D Printer
Calibrating the
Load Cells
6–36
Load cells are sensors that measure the weight of the printing cartridges 
and the waste container in the printer. It is important that you periodically 
check that the weight measurements are accurate, both for convenience and 
to prevent unnecessary waste of printing materials. It is recommended that 
you calibrate the load cells once a month, with the Load Cell Calibration 
Wizard.
To calibrate load cells:
1. Start the Load Cell Calibration Wizard from the Options menu (see 
figure 6‐34 on page 27). 
2. Select one or more load cells that you want to calibrate, and click 
Figure 6-52: Load cell selection
Note: It is recommended that you routinely calibrate all of the load cells,
after 500 hours of printing or once every six months.
3. Remove the cartridge or container, as instructed by the wizard, 
confirm this in the wizard screen, and click 
Figure 6-53: Confirmation of cartridge removal
Next
.
Next