Maintenance Counters - Stratasys J4100 User Manual

3d printing system
Table of Contents

Advertisement

Stratasys J4100 User Guide
Frequency
Every 500 hours of printing
Every 700 hours of printing
Monthly, and after replacing print
heads
Monthly
Monthly
Monthly
Monthly
Every two years or every 2500
hours of printing

Maintenance Counters

The printer computer application records the dates and frequency for each
maintenance task. You can display the Maintenance Counters screen from the
Options menu.
Figure 4-30 Selecting Maintenance Counters
DOC-26000 Rev. C
Task
Replace the wiper.
Replace the roller pump tubes.
Check the alignment of the print heads.
Remove and clean the print-head splash shield.
Clean debris from the Z-axis shaft with a vacuum
cleaner.
Inspect the exhaust system (duct, fan,
connections).
Calibrate the load cells.
Preventive maintenance visit by service engineer.
4 Operating and Maintaining the Printer
For More
Information
See "Cleaning the
Print Heads, UV
Lamp Glass, Roller
and Wiper" on
page 4-37.
See "Replacing the
Roller Waste
Tubes" on page 4-
82.
See "Aligning the
Print Heads" on
page 4-49.
See "Cleaning the
Print-Head Splash
Shield" on page 4-
54.
See "Calibrating the
Load Cells" on
page 4-87.
Contact your
Stratasys service
provider.