6. Click Done in the final wizard screen.

Replacing the UV Lamps

The UV lamps used for curing models have a long, but limited, working life. You
can test and adjust their effective power with the UV Calibration wizard (see
"Testing and Calibrating the UV Lamps" on page 4-74). If you need to replace a
UV lamp bulb or UV reflector, follow these instructions:
To replace the UV lamp bulb or UV reflector:
1. Make sure the printer is in offline mode.
Warning
Before continuing, make sure that the safety interlock is not defeated, and that
the UV lamp is not hot.
DOC-26000 Rev. C
Figure 4-125 Final wizard screen
Figure 4-126 Offline mode indicator (red)
The online/offline button at the bottom of the printer interface should be red. If
not, click it to switch the printer to offline mode.