Calibrating the Load Cells
Load cells are sensors that measure the weight of the material cartridges and 
the waste container in the printer. It is important that you periodically check that 
the weight measurements are accurate to prevent unnecessary waste of 
printing materials or printer malfunctions.
To calibrate load cells:
1.  Start the Load Cell Calibration wizard from the Options menu.
2.  In the following screen, select one or more load cells that you want to 
3.  Remove each selected cartridge from the materials cart, and click Next.
4.  In the next wizard screen, observe the numbers and wait until the weight 
DOC-37004 Rev. J
calibrate. 
Figure 6-102    Load cell selection
Figure 6-103    Confirmation of cartridge removal
level is relatively stable—two units above or below the average level 