Test Fixture Modules - Keysight PD1500A Installation And Use Manual

Si/sic test fixture and modules
Hide thumbs Also See for PD1500A:
Table of Contents

Advertisement

PD1000A Test Fixture for the PD1500A Double-Pulse Test System

Test Fixture Modules

The following table lists optional modules for the PD1000-68701 Test Fixture:
Description
Isolated Low-Side Gate Drive Modules
PD1000-66540 No installed Gate Resistor
PD1000-66542 0  (2x 0 Gate Resistor
PD1000-66544 10 (2x 4.99 Gate Resistor
PD1000-66546 100 (2x 50  Gate Resistor
Isolated High-Side Gate Drive Modules
PD1000-66541 No installed Gate Resistor
PD1000-66543 0  (2x 0 Gate Resistor
PD1000-66545 10 (2x 4.99  Gate Resistor
PD1000-66547 100 (2x 50  Gate Resistor
Clamp Module PD1000-66505
Note: The Clamp module should be installed only
when running the Clamp DPT test. when running
either the Standard or Reverse Test, remove the
Clamp module.
DUT Module for TO-247-3 for 3-pin devices
PD1000-60901
DUT Module for T0-247-4 for 4-pin devices
PD1000-60902
DUT Module for D
(TO-263) devices
PD1000-62401
PD1000-61901 Coaxial Shunt Resistor
Installs on the TO-247 or D
PD1000-62001 Device heater with integrated type K
thermocouple, device clamp
1 These Gate Drive modules use the Texas Instruments UCC5390 Single Channel Isolated Gate Driver IC.
2 See Appendix A for instructions on selecting gate resistors (R
installation, module requires Gate Resistance Rg calibration.
Keysight Double-Pulse Test Fixture Installation and Use Guide
1
2
1
2
2
PAK 7-pin
2
PAK DUT modules
Photos below are representative, what you receive may be
slightly different.
). See Appendix B for instructions on installing custom gate resistors. After
G