Keysight PD1500A Installation And Use Manual page 35

Si/sic test fixture and modules
Hide thumbs Also See for PD1500A:
Table of Contents

Advertisement

Gate Drive Modules (Low-Side and High-Side)
I
header pins
G
for N2819A
Differential
Oscilloscope
probe
Header
Socket to
Test Fixture
Header
Socket to
Test Fixture
Figure 11
High-Side and Low-Side Gate Drive Modules
Keysight Double-Pulse Test Fixture Installation and Use Guide
Low-Side Gate Drive Module
High-Side Gate Drive
Make certain the V/NC header jumper is in place before running a
Double-Pulse Test.
The I/NO jumper MUST NOT be connected when executing a
double-pulse test. This could damage the Gate Drive module.
Double-Pulse Test Preparation
V
/V
Oscilloscope Probe
GS
GE
socket
Header Jumpers
IMPORTANT:
See Caution
below.
Header Socket to DUT Module
No connectors
on High-Side
Gate Drive
Header Socket to DUT Module
35

Advertisement

Table of Contents
loading