Download Print this page

Kenwood NX-1200 Series Function Reference page 19

Hide thumbs Also See for NX-1200 Series:

Advertisement

3 DMR function
Initiating Voice Communications (Basic Transmission and Reception) (Own ID)
Type
Description
Operating the transceiver
Note
Configuration using FPU
Initiating Voice Communications (Basic Transmission and Reception) (Auto Reset Timer)
Type
Description
Operating the transceiver
Note
Configuration using FPU
'■ Standard model
■ Basic model
To initiate various communications using DMR, a Unit ID, the identification code of a transceiver, needs to be
configured for the transceiver.
-
-
Unit ID, Global ID, Unit ID Name, Global ID Name :
Edit > Zone Information > Zone Edit - Conventional Group > ID (Own) > DMR
'■ Standard model
■ Basic model
Auto Reset Timer is the amount of time from when the received Unit ID or Group ID matches the Unit ID or
Group ID preconfigured for the transceiver until the LCD, blinking of LED and emission of Alert Tone will
automatically be reset.
By using KPG-D6/ D6N, Auto Reset Timer can be configured. Also, how the transceiver behaves after the
length of time configured in Auto Reset Timer elapses can be configured.
Configuration
Auto Reset Timer
Off
(Voice or
0 sec to 300
Message)
sec
LCD (Voice or Message)
LED (Voice only)
Alert Tone (Voice or Message)
-
 Respective Auto Reset Timer can be configured for each voice communication (Voice) and data
communication (Message).
 Basic Model has no LCD setting.
Auto Reset Timer, LCD, LED, Alert Tone :
Edit > DMR > Conventional 2 > Auto Reset > Voice
Auto Reset Timer, LCD, Alert Tone :
Edit > DMR > Conventional 2 > Auto Reset > Message
-
Auto Reset Timer
Auto Reset Timer will not be activated.
After the configured time elapses, the matching state of the Unit
ID or Group ID is automatically reset.
While this function is enabled, the display will change from one of
the following displays to the previous channel display if the
amount of time configured for Auto Reset Timer elapses.
 ID display after receiving an Individual Call or Group Call
 Status Message display after receiving a Status Message
 Short Message display after receiving a Short Message
If this function is enabled, the flashing Busy LED for the
Selective Call Alert LED turns off when the length of time
configured in Auto Reset Timer elapses.
If this function is enabled, the intermittently emitted Alert Tone
stops when the length of time configured in Auto Reset Timer
elapses.
-
19
Description

Advertisement

loading

This manual is also suitable for:

Nx-1300 seriesNx-1200 n k2Nx-1200 n кNx-1300 n k5Nx-1300 n k4Nx-1200 d k2 ... Show all