1.3.3
Programming
Requirement
● Correct configuration of the corresponding I/O ranges.
● PLC must actually be able to provide the required I/O ranges (useful-data slots).
● The configured I/O ranges are released for use only when the PROFIBUS-
1.3.3.1
Communication via part programs/synchronous actions
General
The NCK global system variables enable access to the PROFIBUS-I/O, whether read or
write, from the part programs/synchronous actions:
● $A_DPx_IN [n,m]
● $A_DPx_OUT [n,m]
Please note the following:
● When reading from or writing to these variables from the part programs, a preprocessing
● To ensure data consistency during programming from the part program and the
● If the same PROFIBUS-I/O data are to be write-accessed several times within an IPO
● The PROFIBUS-I/O data to be written is printed at the PROFIBUS-I/O only after the
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
communication interface is able to do a data exchange with the corresponding
PROFIBUS-I/O for the first time.
stop is triggered.
synchronous actions, the PROFIBUS-I/O data are accessed, which are kept consistent
for the respective IPO cycle.
cycle (e.g. synchronous actions, access from different channels, etc.), then the data of
the last write access respectively are valid.
corresponding IPO cycle.
A4: Digital and analog NCK I/Os
1.3 NCK I/O via PROFIBUS - only 840D sl
61