Siemens SINUMERIK 840D sl Function Manual page 200

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.15 Examples
Bus identification
[param network]
bus = OPI; OPI bus (1.5 Mbaud)
HMI description
[param MMC_1]
mmc_typ
mmc_bustyp
mmc_address
mstt_address
name
start_mode
Description of NCU components
[param NCU_1]
type = NCU_572 ; NCU type
nck_address = 20 ; Address j of NCU component on the bus
plc_address = 20 ; Address p of PLC component on the bus
name = NCU1 ; name of NCU
[param NCU_2]
type = NCU_572 ; NCU type
nck_address = 21 ; Address j of NCU component on the bus
plc_address = 21 ; Address p of PLC component on the bus
name = NCU2 ; name of NCU
[param NCU_3]
type = NCU_572 ; NCU type
nck_address = 22 ; Address j of NCU component on the bus
plc_address = 22 ; Address p of PLC component on the bus
name = NCU3 ; name of NCU
[param NCU_4]
type = NCU_572 ; NCU type
nck_address = 23 ; Address j of NCU component on the bus
plc_address = 23 ; Address p of PLC component on the bus
name = NCU4 ; name of NCU
; End of descriptive entry
200
= 40
; = 0100 0000: HMI is server and main control panel
= OPI
; Bus the HMI is attached to
= 10
; HMI address
= 6
; Address of the MCP to be switched simultaneously
= MMC_LINKS
; Name of operator panel
= ONLINE
; HMI is connected to the DEFAULT NCU in online
mode
; on power up in accordance with channel data, see
below
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
Extended Functions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de slSinumerik 828d

Table of Contents