B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
The following machine data is used to define which NCU possesses the axis after power up
or is producing the interpolation value.
MD10002 $MN_AXCONF_LOGIC_MACHAX_TAB
Since the axial machine data of link axes are the same on all NCUs, the machine data below
is only evaluated if the NCU also has write authorization to the axis (see MD 10002):
MD30550 $MA_AXCONF_ASSIGN_MASTER_CHAN
Axis replacement
Passing the write authorization to an axis (setpoint input) by means of GET, RELEASE, ..., ,
..., works for a container axis in the same way as for a normal axis. Write authorization can
only be exchanged between the channels of one NCU. Write authorization cannot be passed
beyond the boundaries of an NCU.
2.7.1

System variables for axis containers

States of axis containers
The following system variables allow part programs and synchronized actions to access
information about the current state of an axis container.
Legend:
r: Read
PP: Part program
SA: Synchronized action
SW: Software version
n: Axis container identifier