B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.15 Examples
We must differentiate between two cases here:
1. MMC_1 can change to passive operating mode:
2. MMC_1 cannot change to the passive operating mode (processes which do not permit a
208
MMC_1 changes from active to passive operating mode and acknowledges the
changeover with
MMC1_ACTIVE_CHANGED = FALSE.
If an MCP is assigned to the MMC and activated, it is now deactivated by the PLC.
The PLC gives permission for a changeover to the active operating mode with
MMC2_ACTIVE_PERM = TRUE.
MMC_2 changes state and acknowledges with MMC2_ACTIVE_CHANGED = TRUE. If
an MCP is assigned to MMC_2, it is now activated by the PLC.
changover are running on MMC_1):
MMC_1 sets MMC1_CHANGE_DENIED = TRUE, the change of state cannot be
completed.
The PLC acknowledges with MMC1_CHANGE_DENIED = FALSE and gives permission
to MMC_1 to remain in active mode with MMC1_ACTIVE_PERM = TRUE. By sending
MMC2_CHANGE_DENIED = TRUE, it notifies MMC_2 that MMC_1 cannot switch over to
passive mode.
MMC_2 then acknowledges with MMC2_CHANGE_DENIED = FALSE and remains in
passive operating mode.