B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
Features
The operating characteristics are as follows when several NCUs are linked to one operator
panel:
● NCU operation:
● HMI Embedded:
● HMI Advanced:
OEM solution
As an OEM solution, a PCU with HMI Advanced can be connected via an OPI to up to three
NCUs as a program and alarm server (m=1, n=3).
A PG with a commissioning tool can also be connected.
Figure 2-6
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
The user must select the NCU to be operated by means of a softkey.
The operator display in the "Connection" operating area displays the name of the
connection and of the NCU to which the operator panel is currently linked.
– No application should be active on the connection which is interrupted by the
changeover to another NCU (Example: data backup via V24). System message "V24
active" is output if an attempt is made to switch over the link when an application is
active.
– The HMI is in the default Start operating area for the new connection (as after HMI
restart).
When a link to another NCU is set up, the last operating area selected on the previous
NCU is immediately available for the new NCU.