T1: Indexing axes
16.5 Equidistant index intervals
Couplings
A Hirth tooth system axis can never be one of the following axis types:
● following axis with master value coupling
● coupled-motion axis
● gantry following axis
References:
/FB3/ Function Manual, Special Functions; Coupled axes and ESR (M3)
16.5.5
Modified activation of machine data
RESET
A RESET is required in order to activate the following machine data after new values have
been assigned to them.
MD10900 $MN_INDEX_AX_LENGTH_POS_TAB_1
MD10920 $MN_INDEX_AX_LENGTH_POS_TAB_2
MD10910 $MN_INDEX_AX_POS_TAB_1
MD10930 $MN_INDEX_AX_POS_TAB_2
MD30500 $MA_INDEX_AX_ASSIGN_POS_TAB
958
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
Extended Functions