Siemens SINUMERIK 840D sl Function Manual page 132

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.3 Several operator panel fronts and NCUs, standard functionality
Syntactic declarations
The configuration file must be generated as an ASCII file. The syntax is the same as that
used in Windows *.ini" files.
In the following tables, the components which the user may need to adapt are printed in
italics
lower-case letters. Comments can be entered, provided they start with ";" and are limited on
the right by the end of line. Blanks may be used as separators at any position except for in
identifiers and parameters.
Number of configuration files
A configuration file is required for every operator panel connected.
The configuration files of different operator panels in a configuration differ from one another
only in the first entry, which contains the assignment of the file to a specific operator panel
([own] see below). For practical purposes, the core of the file is generated only once and
then copied for the second operator panel. The identifier of the operator panel to which the
file applies is then inserted in the copy.
I. Identification of operator panel
Identification of operator panel to which the configuration file applies.
Table 2- 1
Descriptive entry
Header
Next line
Identifier:
identifier according to IV.
Vocabulary words:
own:Introduces identification entry
owner
II. Connections
Description of connections from the operator panel components to the NCU to be addressed.
An entry of the following type is required for each operator panel.
Table 2- 2
Descriptive entry
Header
Next line(s)
132
. Alternative parameters are specified separated by a |. Parameters must be entered in
Identification of operator panel front
A descriptive entry for an operator panel must be generated with the selected
Description of connections
Formal
[own]
Identifier
owner =
Formal
Identifier
[conn
]
NCU_ID
conn_i =
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
Example
[own]
owner = MMC_2
Example
[conn MMC_1]
conn_1 = NCU_1
Extended Functions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de slSinumerik 828d