Siemens SINUMERIK 840D sl Function Manual page 133

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
Identifier:
identifier according to IV.
NCU_ID:
according to V.
Vocabulary words:
conn: Introduces connection entry
conn_i: Password for connection, i = 1, 2, ..., 8.
III. Description of bus
The hardware allows links to be implemented via different buses which are differentiated
mainly by their baud rates. The bus type used must be specified.
Table 2- 3
Descriptive entry
Header
Next line
Vocabulary words:
param network Introduces descriptive entry for network
bus: Bus
opi: Operator panel front interface with 1.5 Mbaud
mpi: Multi Point Interface with 187.5 Kbaud
Note
The baud rate is automatically detected on the HMI Embedded.
IV. Description of operator component(s)
A separate entry must be generated for each operator panel connected to the bus. A
maximum of two entries in SW 3.x.
Table 2- 4
Descriptive entry
Header
Next lines (optional)
(optional)
Identifier:
bel_name:
mmc_100
j:
Address of operator component on the bus:
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
2.3 Several operator panel fronts and NCUs, standard functionality
A descriptive entry for an operator panel front must be generated with the selected
A descriptive entry for the NCU must be generated with the selected NCU identifier
Description of bus
Description of operator component
Formal
[param
name=
mmc_100 | mmc_102 | op_030
type=
mmc_address = j
Entry for first or second operator panel
User-defined name with a maximum of 32 characters
mmc_102
op_030
|
|
: Operator component type
Formal
[param network]
bus = opi | mpi
Identifier
]
any_name
j
= 1, 2, ... 31
Example
[param network]
bus= opi
Example
[param MMC_1]
name = MMC_A
type = mmc_100
mmc_address = 1