B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
2.14.6
NCU link with different interpolation cycles
Availability
NCU link with different interpolation cycles is an option.
All requirements that apply for link axes must be fulfilled.
If the non-local axes - seen from the point of view of the NCU with the fast interpolation
cycle - are container axes (e.g. with multi-spindle turning machines) the corresponding
option must also be installed.
2.15
Examples
2.15
2.15.1
Configuration file NETNAMES.INI with control unit management option
A sample configuration file NETNAMES.INI for the MMC 1 control unit for a system with four
NCUs on the OPI is outlined below.
See Section "Structure of configuration file" for details.
Note
The marginal notes (bold print) on the left of the page serve to structure the information and
are not part of the file.
; NETNAMES.INI Example 1 Start
HMI identification
; Identification entry
[own]
owner = MMC_1
PCU-NCU connections
; Connection entry
[conn MMC_1]
conn_1 = NCU_1 ; NCU 1
conn_2 = NCU_2 ; NCU 2
conn_3 = NCU_3 ; NCU 3
conn_4 = NCU_4 ; NCU 4
Extended Functions
Function Manual, 09/2009, 6FC5397-1BP20-0BA0
2.15 Examples
199